Phone: 408-331-1970   Hours: 9AM-5PM PST

EMail: sales@cncrepair.com

 

Before you call, please have written down: the manufacture and item part number. Additionally, for servo and spindle drives, please record any alarm info (LED indications, alarm number, failure conditions). Alarm numbers read from your CNC monitor are not complete. Look in the back, on the item, for the CRUCIAL alarm info.

 

Search for more parts

 

CNCREPAIR.COM:Megger

Manufacturer:

CNC

Part Number:

CNCREPAIR.COM:Megger

Historical Price:

0.00

Description:

Megger. Biddle Instruments 210900 Megger. For Loan Use only. Completely Disconnect motor from drive. Connect Black lead to motor/earth ground, Connect Red lead to one motor lead (1of the 3 with an AC motor, 1 of the 2 armature wires with a DC motor). Turn Megger on (switch to 500V, then hold switch to 200M) The display should show in the high meg ohms. On DC motor, check field (J,K) windings next. Next, short the Megger leads together, hold switch to 200M and confirm the display shows. 0 ohms (reality check that Megger is ok). Please promptly return Megger, packing carefully in our box.